QDS05CS11 Displacement transducer: Nominal capacity +/– 1 mm
The very compact QDS05CS11 displacement sensor consists almost entirely of a coil body and a plunger. This enables the sensor to be perfectly integrated into the relevant equipment, system or test bench. The temperature range is from -55°C to +130°C. QDS05CS11 displacement sensor can be moved in both directions from the central position.
The coil body contains two measuring coils that form an inductive half-bridge. This must be set up in a 4.8kHz carrier frequency amplifier to form a full-bridge circuit.
Nominal capacity: 0…±1 mm
Measuring principle: Inductive half-bridge, based on the principle of differential inductance
Temperature range: –55 °C… +130°C
Output signal: ±80 mV/V
Carrier frequency: 4.8 kHz
Miniature design
There are only two basic parts: the coil body and the plunger
Open design: no unnecessary housings
half-bridge circuits in sensors; formed in the amplifier
Full bridge coil body dimensions: diameter 12 mm x length 20 mm
Wide range of applications
Wide temperature range from –55 °C to +130 °C
High impact resistance: up to 500 m/s2 for coil bodies and up to 1000 m/s2 for plungers
Light weight: 11 grams for coil body, 3 grams for plunger
Application-oriented
It is easy and convenient to install by clamping the coil body
The fine thread on the plunger ensures precise zero setting
Wear-free measuring principle
Continuous plunger channels prevent damage due to excessive stroke
Space-saving and designed for direct integration
It is widely used in equipment, systems and test benches
Practical construction: simple, sturdy and reliable.